Home  |  Search  |  Sitemap  |  Korean  

  About  |  Products  |  Services  |  Support  |  Information  | Contact  |  Links

NMEA Interface


NMEA Combiner/Mux

 8ch NMEA Combiner(Mux)

16ch NMEA Combiner(Mux)


NMEA Combiner (Multiplexer)

NMEA Combiner, NMEA Multiplexer for VDR, S-VDR, ECDIS, AIS, GPS

ZNC-580

8ch NMEA Combiner (Multiplexer)

 


(180x47x115mm)

(Brochure)

(Setup program)

This ZNC-580 NMEA Combiner (NMEA Multiplexer) combines up to 8 NMEA-0183 input data and let out it through 2 NMEA-0183 output ports and 1 RS-232 port.  This is very useful for any equipment such ECDIS and VDR required receiving various NMEA-0183 data from many devices (multiple talkers – single or multiple listeners environment).

ZNC-580 NMEA Multiplexer has the function of NMEA data filtering for each input and output port.  This allows to filter out unwanted NMEA data and reduce the traffic combined NMEA data output.

 

1. Features

˛    Combine enough 8 NMEA input data and output it through 3 independent output ports.

˛    All input and output ports have its own “Filter table” for either passing or filtering NMEA data. This allows to filter out unwanted NMEA data and reduce the combined NMEA data output.

˛    If error rate of each input data exceeds pre-defined error rate, audible and visible alarm is on.  This alerts to do preventive maintenance, and the system reliability can be upgraded.

˛    One RS-232 serial port is available for connection to a personal computer or other RS-232 device.

˛    Easy configuration through RS-232 port with using PC and standard program such Hyper-terminal.

˛    All NMEA input ports are opto-isolated for fully compliant with NMEA-0183 standard, and protected from over voltage.

2. Specifications
 - Input : 9 ch (8 NMEA-0183 + 1 RS-232 Rx Ports)
 - Output : 3 ch (2 NMEA-0183 + 1 RS-232 Tx Ports)
 - Indicator : 13 LEDs (Each Input, Each Output, Input Power)
 - Filtering : Each port can have up to 15 NMEA lists for passing/filtering.
 - Error rate low : 0~20% (default 2%)
 - Error rate high : 10~99% (default 20%).
 -
Dimension : 180 x 47 x 115 mm.
 - Input power : 24V DC (18~32V DC)

3. Option
 - Input power : 12V DC (9~18V DC)


ZNC-516

16 ch NMEA Combiner
(Multiplexer)

TCP/IP Ethernet
Support

(Contact us for details)

This ZNC-516 NMEA Combiner combines up to 16 NMEA-0183(HS) input data and let out it through Ethernet using TCP/IP protocol.  4ch have both input and output port, and it can be configured for RS-422/485/232 and support IEC61162-2(NMEA-0183HS).

This is very useful for such VDR and ECDIS required receiving various NMEA-0183 data from many other equipments.

 

1. Features

˛    Combine enough 16 NMEA input data and output it through Ethernet using TCP/IP protocol.

˛    One RS-232 serial port is available for connection to such personal computer or other RS-232 device.

˛    Easy configuration through RS-232 port and Ethernet using telnet protocol.

˛    All NMEA input ports are opto-isolated and protected from over voltage input.

˛    12 NMEA input ports are compliant with NMEA-0183 (IEC61162-1), and 4 NMEA input/output ports are compliant with NMEA-0183 High speed standard (IEC61162-2).

 

2. Specifications

 - Serial Input : 16 ch

 - Serial Input/Output : 4 ch (RS-232/422/485 selectable by DIP SW)

 - Baudrate : 1,200~115,200bps (All serial input/Output ports)

 - Output : Ethernet using TCP/IP protocol (Socket, telnet, http)

 - Input power : 24V DC (18~32V DC)

 - Dimension :


© Copyright 2007 Zinnos Inc.

Zinnos Inc.
Marine Center 503, Korea Maritime University 
Dongsam-dong 1, Yeongdo-gu, Busan, 606-791, Korea
Tel:+82.51.404.3454,  Fax:+82.51.404.3421
info@digitalmarine.kr, www.digitalmarine.kr, www.zinnos.com